Troubleshooting ​

Bridge status is missing ​

Make sure the bridge starts in a terminal with its environment sourced.

bash
source /opt/ros/jazzy/setup.bash
source ~/ros2_ws/install/setup.bash
ros2 run pylon_bridge udp_bridge --host 127.0.0.1 --port 49010

Source the same ROS setup and workspace in other terminals too. /pylon/status exists even when KSP is not running.

If ROS_DISTRO is not jazzy, use a new terminal and source /opt/ros/jazzy/setup.bash; do not reuse a shell that sourced Humble.

Sensor topics are missing ​

LiDAR and camera topics are dynamic. Check:

  1. The vessel with the relevant part is in Flight.
  2. Sensor and UDP are enabled in the Part Action Window.
  3. KSP PYLON_TRANSPORT.stateHost / PYLON_TRANSPORT.statePort match bridge --host / --port.
  4. Scans or complete camera frames actually reach the bridge.
  5. --topic-timeout-sec is longer than the sensor interval.

Topics disappear after about three seconds ​

Dynamic sensor publishers are removed three seconds after the last data by default. Increase the timeout for slower sensors.

bash
ros2 run pylon_bridge udp_bridge \
  --host 127.0.0.1 \
  --topic-timeout-sec 10

Motors do not move ​

  • Copy the actual joint name from /ksp_vessel/joint_states.name.
  • Check MotorCommand.id, lease, and increasing sequence.
  • Specify servo positions in rad and linear positions in m.
  • Attach bottom to the parent and moving structure to top.
  • Check power, engage, and lock in KSP's Part Action Window.
  • Match bridge --command-host / --command-port and shared PYLON_TRANSPORT.commandPort.

Velocity commands or thrust stop quickly ​

This is normal failsafe behavior. Send commands faster than their timeout with increasing sequence in the same lease. ros2 topic pub -r with a fixed sequence is rejected as replay; use a controller node such as pylon_vehicle_control for continuous control.

Vessel is missing in RViz ​

bash
ros2 topic echo --once /ksp_vessel/root_frame
ros2 topic echo --once /ksp_vessel/robot_description

An empty string means the model was cleared or expired. Check shared PYLON_MODEL.enabled, the UDP path, and permissions on both ends for remote use. Use the root_frame topic's value as RViz Fixed Frame.

Camera images are intermittent ​

Camera frames publish only when all UDP chunks arrive. Start with 160 × 120 or a lower frame rate. Across a network, raw RGB is split into many UDP datagrams and is more sensitive to packet loss.

KSP DLL does not update ​

KSP cannot reload a new DLL while running. Exit KSP, rerun ./sync.sh, then restart KSP.